Subject,Include,Uncertain,Exclude,Notes sub-001,1,,,Small head-nod around slice 34-36 causing large change in signal intensity in some voxels in slice 7. Evident in raw data but corrected for in motion-corrected. sub-002,1,,,"Poor SNR in the lowest slices, but good SNR across cortex" sub-003,,,1,"Excessive motion, striping caused by motion, skull wrapping on functional scan" sub-004,1,,, sub-005,1,,, sub-006,1,,, sub-007,1,,, sub-008,1,,, sub-009,,,1,Excessive motion sub-010,,1,,Motion (causing striping around volume 106) sub-011,1,,,Wrapping on functional scan overlaps at front of the brain (but only affects a few voxels) sub-012,,,1,Excessive motion sub-013,,,1,Excessive motion sub-014,1,,, sub-015,1,,, sub-016,,1,,"2 large signal spikes (causing subsequent dropout), 2 smaller signal spikes. Everything else looks good." sub-017,,,1,Excessive motion (38 relative movements >0.5mm) sub-018,,,1,Excessive motion (max absolute movement = 2.3 sub-019,,,, sub-020,,,, sub-021,,,, sub-022,,,, sub-023,,,, sub-024,,,, sub-025,1,,,Motion around 180-185 does not cause signal dropout sub-026,,,1,Excessive motion (10 relative movements >0.5mm) sub-027,,,1,Excessive motion (6 relative movements >0.5mm) sub-028,1,,,Wrapping on functional scan does not overlap brain sub-029,,,1,Excessive motion (10 relative movements >0.5mm) sub-030,1,,,Poor SNR outside cortex sub-101,1,,, sub-102,,1,,1 huge movement at the end (volume 154). Could this be cropped volume-wise? sub-103,1,,, sub-104,1,,,"Signal change looks like it's caused by eyemovemtn, although the slice numbers don't match up as expected" sub-105,,,1,Excessive motion (7 relative movements >0.5mm) sub-106,,1,,Bordeline motion issues. Peaks likely caused by eyes based on slice location and visual inspection. sub-107,,,1,Excessive motion (max absolute movement = 2.2) sub-108,1,,,Small head-nod around slice 102-104 sub-109,1,,,Lovely blood vessels on T1 sub-110,1,,,Peaks caused by eye movment sub-111,1,,, sub-112,1,,, sub-113,,,, sub-114,,,, sub-115,,,, sub-116,,,, sub-117,1,,, sub-118,,,1,Excessive motion (6 relative movements >0.5mm + max absolute movement = 2.0044) sub-119,,1,,Motion around volume 20 causes global signal drop. Additional motion 107-108 sub-120,1,,, sub-201,1,,, sub-202,1,,, sub-203,,1,,"Enlarged right ventricle. Motion at volume 89 is actually small, large signal change is result of ventricle." sub-204,1,,,Signal spikes at 104 outside of cortex sub-205,1,,,Signal spikes outside of cortex sub-206,1,,, sub-207,,,1,Excessive motion (11 relative movements >0.5mm) + two huge signal spikes sub-208,,1,,Two periods of movement causing global signal dropout sub-209,1,,, sub-210,1,,, sub-211,1,,, sub-212,1,,, sub-213,,,, sub-214,,,, sub-215,,,, sub-216,,,, sub-217,1,,, sub-218,1,,,Signal spikes outside of cortex sub-219,1,,,Signal spikes outside of cortex sub-220,1,,,Signal spikes outside of cortex sub-301,1,,,Signal spikes outside of cortex sub-302,1,,, sub-303,1,,, sub-304,1,,, sub-305,1,,, sub-306,1,,, sub-307,1,,,Constant small motion sub-308,1,,,Slice SNR at borderline between brain and skull sub-309,1,,, sub-310,1,,, sub-311,,,, sub-312,,,, sub-313,,,, sub-314,,,1,Artefact on slice 23 of functional scan + multiple movements causing subsequent global signal dropout and affecting cortex sub-315,,1,,Abnormality (high intensity voxels on T1 (155x132x121) with weird signal blackspot on functional (31x91x52) sub-316,1,,, sub-401,1,,, sub-402,1,,,Signal spikes due to eye movement sub-403,1,,, sub-404,1,,,Signal spikes due to eye movement sub-405,,1,,"Possible pathology? Wouldn't impair registration, but exclude based on participant eligibility for study" sub-406,1,,, sub-407,1,,,Poor slice-wise SNR in brainstem sub-408,1,,,Signal spikes due to eye movement sub-409,,,1,Two large spikes - volumes 38 and 121 sub-410,1,,,Spikes caused by eye moment sub-411,1,,, sub-412,1,,, sub-413,1,,, sub-414,1,,, sub-415,1,,,Spikes caused by eye moment sub-416,,,, sub-417,,,, sub-418,,,, sub-419,,,, sub-420,1,,,Poor SNR in brainstem. Manual inspection of functional scan at signal spikes doesn't appear problematic sub-421,1,,, sub-422,,1,,Would exclude if being conservative sub-423,1,,,Poor SNR in brainstem sub-701,1,,,Poor SNR in brainstem sub-702,1,,, sub-703,,1,,Would exclude if being conservative sub-704,1,,, sub-705,1,,,Poor SNR in brainstem. Squished left cerebellum (CSF). sub-706,,,1,Excessive motion: 12 relative movements >0.5. Manifests as poor quality data in pyfmriqc plots sub-707,1,,,"Visual inspection of functional run does not suggest spikes are problematic. Apparent square signal dropout around slice 26 is non-pathological anatomy, and not sufficient to cause problems with registration." sub-708,1,,,Poor SNR in brainstem. Movement is eye movement. sub-709,,,1,Two large spikes leading to global signal reduction. Affects cortex sub-710,1,,,Poor SNR in brainstem. Visual inspection of functional run does not suggest spikes are problematic. sub-711,,,1,"Weird dots around skull (demetalling fail??), but does not affect bet or func. Possible (low-level) striping on functional scan, and multiple signal spikes resulting in global signal reduction. Each one on its own I might accept, but all together is too much" sub-712,1,,, sub-713,,,, sub-714,,,, sub-715,,,, sub-716,,,, sub-717,,1,,"Enlarged left ventricle, but insufficient to prevent registration. Signal blackspots within ventricles. Spike is right at the end of the run. Could the last 2 volumes be cut? Also unlikely to have substantial effect on the analysis" sub-718,,,1,Good data up until volume 150. Spike around 150 shows concerning effects in carpet plot sub-719,1,,, sub-720,1,,,Poor SNR outside cortex